Grbl_Esp32 Alarm 9
Grbl_Esp32AlarmPosition isn't set yet: home first
During homing an axis travelled as far as it's allowed to and never found its limit switch.
Position isn't set yet: home first. Homing didn't finish. (Hamrun's reading)
What to do
- Watch which axis keeps moving without stopping: that's the switch to check.
- Press that switch by hand and watch the pin state in your sender. No change means wiring or a dead switch; always on means the switch setting is inverted ($5).
- Check the axis really reaches the switch: loose pulley, binding axis, or max travel ($130–$132) set shorter than the machine.
- If the machine has no switch on an axis, don't home that axis (homing cycle settings) instead of forcing it.
- Settings sent by another program can be the culprit: compare the controller's $$ settings with the machine maker's.
Name in the Grbl_Esp32 source:
HomingFailApproach. The meaning above is in Hamrun's words; Grbl_Esp32's own message text isn't copied here. sourceGot a different message?
Paste it into the decoder. Hamrun's editor checks your G-code before you run it, so a toolpath that leaves the machine's travel or a missing feed rate is caught before the machine stops. Have the whole file? Check it here, free: it finds the line that triggers this, and the file never leaves your computer.
Related codes
- GRBL 1.1 Alarm 9: During homing an axis travelled as far as it's allowed to and never found its limit switch.
- grblHAL Alarm 9: During homing an axis travelled as far as it's allowed to and never found its limit switch.
- FluidNC Alarm 9: During homing an axis travelled as far as it's allowed to and never found its limit switch.
- uCNC Alarm 9: During homing an axis travelled as far as it's allowed to and never found its limit switch.
- Grbl_Esp32 Alarm 6: Homing was interrupted by a reset before it finished.
- Grbl_Esp32 Alarm 7: The safety door was opened during homing.
- Grbl_Esp32 Alarm 8: After touching a limit switch, the machine backed off but the switch still read as pressed.
Code name taken from the Grbl_Esp32 source on 2026-11-10; the meaning is in Hamrun's words and Grbl_Esp32's message text isn't copied. Steps and the position answer are Hamrun's reading unless marked “firmware says”. User reports are labelled CLAIMED.