uCNC Alarm 8
uCNCAlarmPosition isn't set yet: home first
After touching a limit switch, the machine backed off but the switch still read as pressed.
Position isn't set yet: home first. Homing didn't finish. (Hamrun's reading)
What to do
- Increase the pull-off distance ($27, try 2–3 mm).
- Check the switch isn't stuck or wired so it always reads as pressed (in your sender, the pin state shows as Pn: in the status line).
Name in the uCNC source:
EXEC_ALARM_HOMING_FAIL_PULLOFF. The meaning above is in Hamrun's words; uCNC's own message text isn't copied here. sourceGot a different message?
Paste it into the decoder. Hamrun's editor checks your G-code before you run it, so a toolpath that leaves the machine's travel or a missing feed rate is caught before the machine stops. Have the whole file? Check it here, free: it finds the line that triggers this, and the file never leaves your computer.
Related codes
- GRBL 1.1 Alarm 8: After touching a limit switch, the machine backed off but the switch still read as pressed.
- grblHAL Alarm 8: After touching a limit switch, the machine backed off but the switch still read as pressed.
- FluidNC Alarm 8: After touching a limit switch, the machine backed off but the switch still read as pressed.
- Grbl_Esp32 Alarm 8: After touching a limit switch, the machine backed off but the switch still read as pressed.
- uCNC Alarm 6: Homing was interrupted by a reset before it finished.
- uCNC Alarm 7: The safety door was opened during homing.
- uCNC Alarm 9: During homing an axis travelled as far as it's allowed to and never found its limit switch.
- uCNC Alarm 10: On a machine with two motors on one axis, the second limit switch wasn't found when squaring.
Code name taken from the uCNC source on 2026-11-10; the meaning is in Hamrun's words and uCNC's message text isn't copied. Steps and the position answer are Hamrun's reading unless marked “firmware says”. User reports are labelled CLAIMED.