uCNC Alarm 14
uCNCAlarmPosition is kept
The plasma torch's arc didn't start when the torch height control asked for it.
Position is kept. Hamrun's reading: the arc never started, so the machine stopped before cutting. (Hamrun's reading)
What to do
- Check the consumables (tip and electrode), the air pressure and the ground clamp on the work.
- Check the arc-OK signal from the plasma cutter is wired to the controller.
- Reset and run the cut again.
Name in the uCNC source:
EXEC_ALARM_PLASMA_THC_ARC_START_FAILURE. The meaning above is in Hamrun's words; uCNC's own message text isn't copied here. sourceGot a different message?
Paste it into the decoder. Hamrun's editor checks your G-code before you run it, so a toolpath that leaves the machine's travel or a missing feed rate is caught before the machine stops. Have the whole file? Check it here, free: it finds the line that triggers this, and the file never leaves your computer.
Code name taken from the uCNC source on 2026-11-10; the meaning is in Hamrun's words and uCNC's message text isn't copied. Steps and the position answer are Hamrun's reading unless marked “firmware says”. User reports are labelled CLAIMED.